Only logged in customers who have purchased this product may leave a review.
Inficon – IE414, IE514
$0.00
Advantages
- High accuracy of the measurements due to individually calibrated sensing system
- Exchangeable cathode
- Extreme high temperature bake-out up to 400 °C
IE414
- Bayard-Alpert sensing principle
- Measurement range to 2×10-11 mbar
- Modulation of the cathode emission current (in combination with the IM540 vacuum gauge controller)
IE514
- Extractor sensing principle
- Lowest measurement limit, down to 2×10-12 mbar
- Significant reduction of X-ray and ion desorption effects
Typical applications
- Scientific and R&D applications requiring precise vacuum measurement in the ultra-high vacuum range and high temperature bake-out
Related products
-
Inficon – Trigon BCG552
$0.00Add to cartAdvantages
- 3 + 1 sensing elements for extremely wide measurement range, cost reduction & space savings
- 2 filaments for Bayard-Alpert system
- Gas type independent pressure measurement above 10 Torr provides more reliable load lock control for any gas mixtures
- Differential pressure measurement eliminates uncertainty related to atmospheric pressure changes
- Automatic high vacuum Pirani adjustment reduces operator interventions
- Galvanic isolated electronics to avoid electric stray current
- Sliding emission mode to avoid pressure jumps and freeze when switching the emission stream
- Set point relays
- Bright & big OLED display (90° rotatable) with user interface
- Analog output, RS232C serial interface, EtherCAT®
- Usable in conjunction with VGC50x Controller series
- Backwards compatible to TripleGauge® BCG450
- RoHS compliance
Typical applications
- Pressure measurement in Semiconductor processes, transfer and loadlock chambers
- Industrial coating
- General vacuum measurement and control on systems in the low to ultra high vacuum range
-
Inficon – Gemini MxG5xx
$0.00Add to cartAdvantages
- Long lifetime in harsh environments
- Low magnetic stray field
- Reliable fast ignition
- Fastest maintenance – replaceable insert
- Compact size – easy to integrate
- Corrosion proof feed-through & sensor element
- Selectable measuring current
- 2 relay setpoints (in conjunction with MxG55x PROFINET and EtherCAT)
- PROFINET, EtherCAT and RS232/ RS485 digital interace
Typical applications
- Base pressure monitoring and control, from atmosphere to high vacuum in evaporation and sputter coating applications.
- General vacuum measurement – industrial furnaces, architectural glass, semiconductor, Refrigeration/ air conditioning and production laboratory`s
- Analytical and R&D applications – mass spectrometry, electron microscopes, ophthalmic, optical, medical and high energy physics.
-
Inficon – PGE500 DeviceNet
$0.00Add to cartAdvantages
- Convection Enhanced Pirani Technology for wide measurement range and higher accuracy near atmosphere
- All-in-One active gauge with built-in display, 2 set points, and digital DeviceNet interface
- Bright digital OLED display with keypad for simple setup, calibration and operation
- Factory pre-set display units for measure or selectable via keypad
- User programmable set point relays (factory pre-set on request for volume orders)
- Gold plated tungsten filament or platinum filament for corrosive applications
- Mechanical strength, highly robust and less susceptible to mechanical shock and vibration
- Field replaceable spare sensor units
- Choice of flange options
- Compliance & standards: CE, RoHS
- Direct drop-in plug-compatible replacement for the DeviceNet versions of MKS / Granville-Phillips® Mini-Convectron® (GP275 Modules) Granville-Phillips® and Mini-Convectron® are registered trademarks of MKS Instruments, Andover, MA
Typical applications
- Fore vacuum pressure measurement
- General vacuum measurement and control form low to the high vacuum range
-
Inficon – BCG450
$0.00Add to cartAdvantages
- BCG450 saves cost and tool space and reduces the complexity of vacuum measurement installation and setup
- Gas-type-independent pressure measurement above 10 Torr provides more reliable loadlock control for any gas mixture
- Pirani interlock protects the hot filament from premature burnout
- Automatic high vacuum Pirani adjustment reduces operator interventions
- Differential pressure measurement at atmosphere eliminates uncertainty related to atmospheric pressure changes
- Easy-to-exchange sensing element with on-board calibration data guarantees reproducibility
- Optional graphic display and Fieldbus interfaces available
- RoHS compliance
Typical applications
- Pressure measurement in Semiconductor process, transfer and loadlock chambers
- Industrial coating
- General vacuum measurement and control on systems in the low to ultra high vacuum range
-
Inficon – Porter CDG020D
$0.00Add to cartBenefits
- Excellent span stability – gas type independent
- Alumina sensor
- Compact, smallest size in it’s class
- Easy integration, any mounting orientation
- Digital signal processing
- Maintenance free
Typical applications
- Vacuum coating
- Vacuum monitoring
- Sterilization
- Food & packaging
- Vacuum oven, puller
- Analytical
- Chemical vacuum processes






Reviews