Only logged in customers who have purchased this product may leave a review.
Inficon – VGC083
Advantages
- Flexible solution for vacuum pressure monitoring and controlling from atmosphere down to ultra-high vacuum
- Clear and simple operation with three individual bright LED displays
- Parameter, sensor and general settings with softkeys
- User selectable filament, degas electron bombardment or I2R resistive heating for gauge conditioning depending on gauge head type
- Three analog outputs, user assignable to a single gauge or to gauges combinations
- Six assignable single pole double throw setpoint relays
- Ion gauge overpressure protection: sensor 1 can be automatically turned on/off from sensor 2 or 3
- Remote digital I/O sensor and emission on/off, RS232 / RS485 serial communication
- Direct drop in replacement opportunity for Granville-Phillips® Bayard-Alpert Gauge Controller 307 and accessories
Related products
-
Inficon – BPG400
Read moreAdvantages
- Extremely wide measurement range from 5×10-10 mbar to atmosphere (3.8×10-10 Torr to atmosphere)
- Excellent repeatability in the process pressure range from 10-8 … 10-2 mbar of 5%
- The Pirani interlock protects the Bayard-Alpert system from premature filament burnout and excess contamination from high pressure operation
- Long-life yttrium oxide coated iridium filament
- Optional graphic display and Fieldbus interfaces available
- Automatic high vacuum Pirani adjustment reduces operator interventions
- RoHS compliance
- General vacuum measurement and control in the low to ultra high vacuum range
Typical applications
- Pressure measurement in semiconductor process and transfer chambers
- Industrial coating
- General vacuum measurement and control in the low to ultra high vacuum range
-
Inficon – PCG55x
Read more- Gas type independent above 10 mbar – allows safe venting with any gas mixture
- High accuracy and reproducibility at atmosphere – for reliable, fast atmospheric pressure detection
- Versatile of mounting orientation – provides engineering freedom in tool design
- Available with Tungsten (PCG550) or Nickel (PCG552) filament or with a fully ceramic coated (PCG554) sensor unit for highly corrosive applications
- Latest EtherCAT protocol Standard ETG.5003.2080 S (R) V1.3.0
- Easy to exchange plug & play sensor element with on-board calibration data – guarantees high reproducibility and low cost of ownership
- Selectable output signal for easy integration
- Optional atmospheric switch, display and digital interfaces
- Compliance & standards: CE, EN, UL, CSA, RoHS
-
Inficon – PGE500 DeviceNet
Read moreAdvantages
- Convection Enhanced Pirani Technology for wide measurement range and higher accuracy near atmosphere
- All-in-One active gauge with built-in display, 2 set points, and digital DeviceNet interface
- Bright digital OLED display with keypad for simple setup, calibration and operation
- Factory pre-set display units for measure or selectable via keypad
- User programmable set point relays (factory pre-set on request for volume orders)
- Gold plated tungsten filament or platinum filament for corrosive applications
- Mechanical strength, highly robust and less susceptible to mechanical shock and vibration
- Field replaceable spare sensor units
- Choice of flange options
- Compliance & standards: CE, RoHS
- Direct drop-in plug-compatible replacement for the DeviceNet versions of MKS / Granville-Phillips® Mini-Convectron® (GP275 Modules) Granville-Phillips® and Mini-Convectron® are registered trademarks of MKS Instruments, Andover, MA
Typical applications
- Fore vacuum pressure measurement
- General vacuum measurement and control form low to the high vacuum range
-
Inficon – PGE300
Read moreAdvantages
- Convection Enhanced Pirani Technology for wide measurement range and higher accuracy near atmosphere
- All-in-One active gauge with built-in display, 1 set point and 3 selectable analog output signals
- Bright digital LED display features a user friendly for calibration and operation
- 3 optional analog output signals (user selectable)
- Factory pre-set analog output signal or selectable via user interface
- Factory pre-set display units or selectable via user interface
- User programmable set point relays
- Gold plated tungsten filament
- Mechanical strength, highly robust and less susceptible to mechanical shock and vibration
- Choice of flange options
- Compliance & standards: CE, RoHS
- Direct drop in replaces most Granville-Phillips® Mini-Convectron® modules (GP275) and ideal device forupgrading your installed thermocouple gauges (Granville-Phillips® and Mini-Convectron® are registered trademarks of MKS Instruments, Andover, MA)
Typical applications
- Fore vacuum pressure measurement
- General vacuum measurement and control from low to the high vacuum range
-
Inficon – BCG450
Read moreAdvantages
- BCG450 saves cost and tool space and reduces the complexity of vacuum measurement installation and setup
- Gas-type-independent pressure measurement above 10 Torr provides more reliable loadlock control for any gas mixture
- Pirani interlock protects the hot filament from premature burnout
- Automatic high vacuum Pirani adjustment reduces operator interventions
- Differential pressure measurement at atmosphere eliminates uncertainty related to atmospheric pressure changes
- Easy-to-exchange sensing element with on-board calibration data guarantees reproducibility
- Optional graphic display and Fieldbus interfaces available
- RoHS compliance
Typical applications
- Pressure measurement in Semiconductor process, transfer and loadlock chambers
- Industrial coating
- General vacuum measurement and control on systems in the low to ultra high vacuum range






Reviews